Thursday, 20 December 2012

Avon Valley National Park, December 2102

As I was on holiday's, the little one had finished school and the other half was still at work, I had a couple of days to fill in. What better opportunity than to get the ulti out for an overnighter.

On the weekend prior, I went for a drive there for reconnaissance. Firstly, to check if the gate was open (which it was) and secondly to check if the steep entrance track would be suitable for haulin the ulti.

I don't think getting down will be a problem (if you miss the ruts from water degregation), but coming up may cause an issue???? only one way to find out I guess.

The site down the bottom was quite large and open. A drop dunny and plenty of picnic tables to be had. Best of all, no people around...Yeah!







Due to unseasonal rainfall, the water levels in the river were exceptionally high






And so it was a goer. Wednesday would be the day for the overnighter. I'll work out how to haul the Ulti back up the hill on Thursday.



Arriving about lunchtime, the journey down the hill wasn't so bad. Using low range for enhanced engine braking was a better move than overheating the brakes on both the Paj and the Ulti. I missed the one big washout with the trailer, so that made me happy. At the bottom, I positioned the trailer and roughly set up the camper so that we could get lunch underway. Kaitlyn must have had a hard year at school because she polished off 3 ham sandwiches, 2 jelly's and 2 beers (Kaitlyn's name for soft drink - if you were wondering)

During sandwich 2, I heard a vehicle and went outside to investigate. It was the ranger. I think he was both shocked and surprised to see me down there with a camper. We chatted a bit and I gave him the grand tour of the xtrk. He was impressed. I then told him about geocaching and that there was one at this campground. So out with the handheld and we gave him a lesson. Again he was impressed. So much so, he didn't bother asking me for camp fee's. I told him we would be gone by lunch on Thursday (if I could haul the ulti back up the hill)





It was starting to warm up by now, so instead of setting up camp fully, I took K for a walk. The river had dropped lots since Sunday, so we decided to go across for an explore on the other side. There was a lot of what I think was an algae going over the causeway. So much, I didn't even entertain the idea of swimming. In fact, you can see the circular shaped floaties in the lower left of this pic. There was lots of it.









The other side of the river was the Westrail access road. I have travelled this road a few times before in my days of the inwater rescue team for the Avon Descent. It was bringing back some memories....and also had me wondering.....I'm thinking that Emu Falls (an Avon Descent day 2 highlight) wasn't that far away.





So we walked up and sat on the side of the cutting, waiting to see a train...After 1/2 hour, no train, so we headed back to camp as we didn't bring water with us. By now it was later afternoon and just the right time to go for a hike. Back over the causeway and waiting by the mainline. It didn't take long for a freight train to come belting through the cutting












After the excitement of the train went through, I coaxed K into going for a walk. I had to see if what I could see on my sat maps on ozi was Emu Falls. And about a kilometer, I was rewarded. It sure was Emu. I Told K of my stories of being in the Avon inwater rescue for a few years, well before she was on the scene. I was stoked to see the place again.











You could only imagine what it is like piloting a 10HP fiberglass bathtub or padling a kayak or ski through this







So with that done, it was time to return to camp to set-up and get ready for dinner. A peaceful and uneventful night followed. K went to bed (finally) and I retired to the red.


Morning came and so did the coffee with bacon and eggs...Yum. The flies were pretty ordinary this morning due to the lack of heat. A leisurely pack up and we were ready to see how I would go haulin the Ulti up the hill.

Once the terrain got a bit steeper and rougher, I went into low range. A few spots were a bit hair raising as all 4 wheels were losing traction trying to haul the 1T slug on the back up the steep and eroded incline. I wouldn't even consider doing this with a camper if its wet. Sucessfully negotiating the ruts with the Ulti still on its wheels we neared the top. And bugger me, the gate was shut....Oh crap, what to do now? There is no way I could reverse down that hill. So I stopped and engaged the handbrake  to see if it would hold. Success.....so a walk to the gate revealed it was only pushed closed, not locked. So I opened the gate and made my way to the top of the hill.






Once through the gate on level ground, I stopped, attached the stone stomper and pushed the gate closed......I firmly believe in the concept that you leave a gate how you found it. Ask any cocky about this principle!






On the way out, I decided to check out the Moondyne's cage cache. I tried to find it on Sunday, but it was too bloody hot and I was sick of all the vegetation sticking to the sweat on my neck and back. And I'm glad I did. Cause I found it second time around and scored a nice travel bug to reposition (probably over xmas when I go down to Nannup). Then a few K's later, I stopped at another cache. This time I scored a nice geocoin to move on.

From there it was a leisurely cruise home, and a quick wash down of the camper and tug. In a couple of day's I'll head South to Nannup. With luck, I'll get a couple of days both before and after xmas to camp in the ulti before heading back to work on new years eve.



EDIT: 30th December...... A week after this trip I discovered a tick buried in K's shoulder on xmas eve. So off to the local for its removal. Then on boxing day, I discovered I was the host for 3 ticks. One in a place very close for comfort. So if your heading Avon NP way, be wary and take the necessary precautions. Luckily, it appears as if there has been no side effects of harbouring the parasites.

Tuesday, 18 December 2012

The Buccaneer Archipelago

PUBLISHED, but UNDER CONSTRUCTION:




Its been a long time coming, but I thought I had better blog this trip of a lifetime from 2006.

17 friends + 1 unborn, 5 boats and 8 days exploring the Kimberley Coast .











 30 Min slide show of trip:






Tuesday, 20 November 2012

Wellington Dam


The culmination of 4 days off and some new canvas for the ulti meant I was going away. Wanted somewhere relatively close to home.

Arriving at the camp site, I'm shocked its so small. All the choice spots were taken by the grey nomads in their vans...figures....

So I decide to check out a spot nearby. This other place is chock-a-block, so after a bit of swearing and thinking of alternative sites, I decide to go back to the original site.

I decided we will stay here, not my idea of an ideal location, but it has the room for me to spread out my new canvas.

In the end, it ended up being not too bad at all, the grey nomads were pretty good.











As I was erecting the canvas, the other two buggered off down the dam to leave me to it. It was pretty warm. Especially being out in the sun trying to work out where all these pieces of new canvas go????

The custom front awning I had made was a pearler.....It was such a nice place to sit in the shade with the cooling breeze blowing. The main awning was a bit hot as the wind was coming from the front annex side of the Ulti.















The little un had been sick and missed Mon/Tue at school due to vomiting. Then she came good, so the weekend was a goer. Unfortunately whilst we were all asleep at 1030pm, she decided to christen the ulti big time.....sh*t...

Luckily most of it was in her pillow, but the ulti copped some all the same. Some how she missed her sleeping bag, so that was a bonus.

After emergency clean ups and some make shift pillow making, we all slept peacefully for the rest of the night. The little un had a tub to take to bed, just in case.

Sunday came around, so I decided to christen my hillbilly frypan I've had for over a year now. What better way to first fire it up than with bacon and eggs for breky.....










Later that afternoon, we decided to go for a bit of an explore. Came across a nice secluded campground. Well it would have been nice if the people who were marroning out of season didn't leave their flyblown scraps in a shopping bag out in the open. (they were nice sized marron too going by the festering shells) Also the toilet was full and neatly packed with the rubbish of previous camping trips. I mean really, If you can carry it in full, why cant you carry it out empty....Grrrrrr
I happened across DEC on the way out and made mention of the poor state of the campground.













The water was crystal clear and relatively deep. I did think about going for a dip at one stage.





Back at camp and we venture off down the dam for a look









what better things do kids have to do but make mud pies







and surf burnt out floating logs








while the rest of us just sit back thinking "how's the serenity"  lol






Some wildlife came in for a better look in the afternoon. Must have been checking out the ulti






Then the 28's came in for a feed. Taken right out of the hand.













but it was now time for more serious aspects of the evening:

firstly, gathering the wood






Then waiting for the coals to build







Monday came and we leisurely packed up. Did a couple of caches on the way out. Had a slight problem with the last. I thought it was time for the girl to step up to the mark and recover the cache and its contents (after I located it that is)

All was well and she was checking out the treasure's. Until....a blood curdling scream was let out. Checking the contents of the cache revealed a small scorpion about an inch long. Whilst mum provided the first aid back at the car, I emptied the cache of scorpion's and made my way back. She had a cold beer on her arm now as the venom was rising from the thumb where she was stung and her arm was swollen and throbbing with pain. As she was in agony, I made a dash for collie hospital to get some "better" pain relief than I had on board. They gave her something to drink and sent us on our way. As it was getting a bit late now, we stopped in town for lunch. Then 10min's after we left, she was zonked for most the trip home. When she woke, you wouldn't know what had happened.

So all in all, a good result and a great weekend, even if marred by some of life's little hiccups.

The Ultimate Caver Trailer

Well after the 6 week jaunt in the caver trailer, I decided I needed a different beast for those long trip, one night stop types of camps. I just sold my boat due to lack of use and the money was burning a hole in my pocket. As luck would have it, I found an 18 month old Ulti for sale locally. I went and had a look at it, the price seemed right, so another chapter begins........



Well, August 2012 and the deal is done.

First pics:











































So I ended up swapping a keeled boat for a wheeled boat!

Lots of mods to do. First up, cutting a hole in the fiberglass to fit the evakool Arrgh!

**********************************************************************************************************************************

Well maybe I'll do the distribution system first......


2 x 100 agm's, inline monitor, redarc bcdc1240 charger, 6 pot fuse box for distribution and an anderson for charging/solar.










I had a slight hiccup with the battery install. I kept all the oem stuff so it can be set up as original if ever needed. As such I had to remove a cable lug. A good plan was to bang a small flat bladed screwdriver in there to force open the crimp. Some light taps did jack. A heavy lunge and the cable lug went sideways and the screwdriver buried into my finger. As you could imagine, I shook my hand in agony, only to have my face, shirt and trailer sprayed with blood. The paving looked like the texas chain saw massacre had just taken place.

A few days later when I washed my hands, my bush stitches (bandaid) slipped off. Only then did I notice both an entry and an exit wound, opposed width wise on my finger. Bloody hell, I punched the driver all the way through.....

So lucky I still have full movement and feeling in the finger.

Let my bad judgement be a lesson for those that like to tinker.

And the ironic part of that....10 lugs cost me $7.00.

So for the sake of 70 cents, I very nearly suffered permanent injury.

What a tight arse I am sometimes

**********************************************************************************************************************************

So after the bats were complete, I got even busier

Got some foam (that's bloody exe) as I decided to make my own bed infill. Some material from spotlight and a few hours on the sewing machine and all should be good.







Then I got busy performing surgery and fitting the fridge.


















Just need to box in the compressor and I should be all set for the inaugural shakedown trip in a couple of weeks.

************************************************************************************************************************************

crap pic (had no control over the sun casting user shadows) but the hole is filled now. Sika'd in place, will screw and seal the outside at some stage.





Also had to cut the shield on my 9kg lpg to fit the locker box. I must say, cutting a partially filled 9kg...not very wise

************************************************************************************************************************************

Got the stomper fitted today. Almost ready for the maiden voyage













************************************************************************************************************************************

And then, the Ulti's cherry was popped








.
************************************************************************************************************************************

I thought I needed some light in the boot.

500mm of 5050 led strip, stuck to 12mm ali flat bar, clear heat shrink over the top of all that. Put an inline switch at the end of the strip  click here

The strip is sika'd to the boot roof, out of harms way. I pulled the cable through the existing split loom tubing from the battery box and routed it out of harms way. The photo doesn't do it justice. It lights all corners of the boot very well :)

Thinking I may just do the same for my internal cupboards








************************************************************************************************************************************

I placed an order for the full annex wall kit, so I can totally enclose the area under the main awning. Great for either insect protection or to create a wet weather area. Also a custom front awning, will come out the drawbar side about 2 meters and supported with poles and ropes. Will provide shade on that side of the camper and wet weather protection should I need to access the boot area. Not a cheap exercise

************************************************************************************************************************************

New canvas arrived on Thursday, just in time for a weekend jaunt.

Very happy. The custom front awning is just superb too.



















************************************************************************************************************************************

End of blog November 2012. Will add to the blog as more mods continue

Friday, 4 May 2012

A Generation of Engels

A quick review and power consumption of a 40L Engel, 30 years apart:

(Edit: March 2014 -What started out as a test of an old and new Engel in regards to power consumption has now slowly developed into a test of consumption of many different fridges and sizes. I note that when researching to purchase a mobile fridge, there are many things to consider. Most of these things are pretty straight forward (size, layout etc). But power consumption is certainly is not straight forward. Non standard units and misleading advertising for example - What draws more power, something that draws 5 amps max or something that uses an average 1.8A/hour ??? Without taking power consumption measurements and/or knowing compressor cycle times, the previous two statements mean little. However the later statement at least has a time based component to it and from that an AmpHour unit per day can be calculated. It is my experience the greater majority of potential customers wouldn't have a clue how to do this nor what it means. This is where this blog post comes in. If you are in the market for a new fridge, and power consumption is a contributing factor of your decision making process (as for most of us it is)  then I hope you gain something constructive from the results below. This will be an evolving document so check in every now and then. But again, I will reiterate:- this is a test performed in at best a constant ambient temp I can achieve with  a standard datum of cold loading of a 6 pack. This test makes no assumptions as to how consumption will change between different fridges with regard to changing ambient's , cold loading and lid opening sequences. So take the results as they are. Cheers.....)



I recently acquired a new generation Engel. One big reason I purchased this was that I had heard their efficiency is very impressive these days. As such, I thought it was worthy to do a bit of a comparo and see how the product has changed over the years.

First up a 2012 MT45FP

and a Model A/B 40L circa early 1980 vintage.








A couple of features I noticed the new has over the old,


 - evaporator plate goes all the way to the floor, unlike the older which only goes 1/2 way to the floor

 - Auto switching power inputs. Always defaults to ac input when available.

 - Led interior light, a bit of a token measure, but better than none I suppose

 - and a cabinet temp gauge

Physical size is about same, metal work is similar but more modern, a far better lid latch and lid hinge mechanism over the older model.








Now for the important details: how do they compare in performance.

The test: All fridges Pre chilled, lightly loaded with a cold 6 pack, kept to approximately 3-5degrees measured with 2 temp probes and run of a wet cell battery for 24 hours to monitor power consumption.


The MT45FP

First up, the cabinet temp gauge was within a degree of the two probes all times I looked, so that's a nice feature, an accurate inbuilt gauge. I do not know the detail on the position where the sensor monitors from.

Over 24 hours the following was noted:

Ah used 11.5
Av running amps 2.6
max amps 3.5


Model A/B

Ah used 26.5
Av running amps 4.8
max amps 5.2



That to me was extremely impressive. The new unit consumes nearly 2.5 times less power than the old.

To add some comparative figures to this, I also have 2  Danfoss powered fridges, both less than 12 months old.

The Waeco CF25 used 13Ah (test result obtained at the same time as above), the Evakool FM70 uses a whopping 50 odd (values obtained from former testing I performed). Admittedly, they are all different sizes, therefore efficiency would and should differ as you would expect due to the large differences in surface area of each unit absorbing heat from its surroundings and the volume of cabinet itself.

Now a fairer comparison would be to test a similar sized 40 odd litre Danfoss unit. Unfortunately, I don't have one of these on hand, so you can draw your own conclusions if you think this comparison is worthy of inclusion or not. You could also argue the test environment, a relatively uniform place in regards to ambient temps is not considered a real world test. At a camp site or in the back of a car, this probably wouldn't happen.

But I suggest, testing in the real world of changing ambient's, is more about testing the fridges insulation performance. I admit this is also very important when deciding upon what fridge to purchase. But as I don't have a controlled environment nor the capacity to test all 3 fridges in the same field at the same time, that is a mute point. The comparison is more about measuring the Fujisawa v's the Danfoss power efficiency. You can modify a fridges thermal insulation relatively easy, add a thermal bag for example. You cant do much with the compressors efficiency. And on that point alone, I believe the above comparison is valid and worthy of mention.


 I feel that the results I posted on the 1/2 sized Waeco CF25 using 18% more power than the new MT45, compressor efficiency is going to go in Engel's favour by a fair way in a similar sized unit as I would expect a similar sized 40L Danfoss fridge to be much greater in consumption then the CF25. I'm happy to be proven wrong. In fact, these results contradict a recent 4WD Action fridge test of which the pdf can be downloaded here:

Click to download PDF: 4WD Action comparo

In that, the Danfoss units performed marginally better in consumption than the Engel. But they did testing in a controlled environment of ramping ambients up and down. 25>0>25 and another from 25>60>25. I feel the 25 degree to 60 degree and back again ramp test to be at the very extreme of what most people would experience.



But in summing up, and I don't want to start an Engel v's the others type of debate, if power efficiency is your goal (as it is for most of us), I just cant see how your next fridge wouldn't be an Engel from the results I posted.







Post Script:

Thinking about the above test, I am going to perform the same test but the power source will be a uniform mains fed dc supply. That way I can discount changes in amperage and voltage as the battery state of charge changes. I will add these new test results below as they come to hand.

Well the results of this are now in. Very similar in differences to just being run on battery alone. And I've added better temp monitoring results than the first test (which I didn't record)



MT45:

Internal temp/Ambient (min):  1.6/18.5

Internal temp/Ambient (max):  2.7/21.6

Amps (peak): 4.4

Average running Amps: 2.6

Ah consumed (24 Hrs):  9.7


Model A/B:

Internal temp/Ambient (Min):  1.8/20.4

Internal temp/Ambient (Max):  2.3/22.3

Amps (peak):  5.25

Average running Amps:  4.7

Ah consumed (24 Hrs):  25


*****************************************************************************************************************************************

And now a few others for comparison:




 Waeco CF25: 






set at 2 degrees on the panel:

Internal temp/Ambient (Min):  0.6/20.7

Internal temp/Ambient (Max):  3.5/21.7

Amps (peak):  6.58

Average running Amps: 4.1

Ah consumed (24 Hrs):  11.8


*****************************************************************************************************************************************


Evakool FM70:






Internal temp/Ambient (Min):  TBA

Internal temp/Ambient (Max):  TBA

Amps (peak):  TBA

Average running Amps: TBA

Ah consumed (24 Hrs):  50Ah


*****************************************************************************************************************************************


EDIT: Jan 2013

 Waeco CF50-DZ:







So I got hold of a Waeco CF50DZ to test. Same BD35 compressor as the CF-25 and the Evakool FM70 I tested previously.

So I expected the result to lie somewhere in between these. I assume the difference in consumption between the fm70 (50Ah) and the cf25 (12Ah) due to the volume differences between the two. I estimated the CF50 to consume around the 30 mark.

Just to refresh the test performed. A pre chilled fridge, with a 6 pack inside with internal temperature set to 5degrees, unopened for 24 hours. I didn't have access to my max/min thermometer, so temps stated are average.

So the results for the CF50DZ (divider removed):

Average Internal temp: 5degrees (set at 2 degrees on the control panel)

Average Ambient Temp:  26 Degrees

Max Amperage drawn: 5.9A

Average running amps: 3.0A

Power Consumption:  16Ah.


That is very good and about 1/2 the power used than I expected. But now it only leaves me more question's to ponder.


I watched the amperage quite a few times when it cycled on. It starts by drawing about 4 amps, then quickly recedes down to 3Amps. Never did I see it draw more than 4A. But my meter logged a 5.9A peak. I wonder when and for how long this occurred?

It's the same compressor as the CF25 and the FM70. Both these run at near 5Amps. They would never run at 3 amps. Why does the CF50 draw so little? I think VMSO is the answer. More on that in the CF80-DZ test below.


I can understand the difference of 12Ah of the CF25 to the 16Ah of the cf50dz as it's twice the volume. I think the efficiency of the CF50 is great in comparison.

However, my main concern now is why does the FM70 draw 3 times the power of the CF50. Its volume is only about 50% greater again than the CF50.

*****************************************************************************************************************************************


EDIT: March 2014


Waeco CF80-DZ:








I have now added a Waeco CF80-DZ to the mix. I was very interested in this one to compare to the FM70 as they are both BD35F compressors and similar litreage.

Just to refresh the test performed. A pre chilled fridge, with a 6 pack inside with internal temperature set to 5degrees, unopened for 24 hours and dividers removed.The 6 pack was placed in the centre of the fridge compartment.

I note that I had to set the panel to 0 degrees to obtain the 5 degree content I was seeking. Most other units tested achieved this at the 2 degree setting.I guess this is due to the fact that the evaporator plate is in the freezer side and relying on thermal transfer between compartments?

I have added another test for future edits. The measuring of the case temperature (inside of any insulated bag if fitted). This will be done with a non-contact IR thermometer to find its coolest temperature. I will then relate this as a value minus current ambient. That should then give some idea as to how the insulation properties differ.

Now, onto the CF80-DZ results:

set at 2 degrees on the panel:

Internal temp max: 5.1

Internal temp min: 4.5

Ambient Temp max:  25.3

Ambient Temp min:  20.6

Amps peak: 7.01

Amps running average: 3.6

Power Consumption: 21.2

Case temp:  5 degrees below ambient



Cycle times: I noted cycle on/off times periodically. You can almost set your watch by it. That was  a bit spooky. 8 Minutes of run time with a rest period of 16 minutes.

VMSO: I have to say, from the two fridges tested thus far with VMSO (CF50 + CF80) , I am a big fan. I love the way it runs and changes speed/draw and start up current dependant upon condition. Whilst it maybe a little early to tell, I suspect this is having a big impact on the compressors overall efficiency.

My research to date tells me this VMSO is a Waeco propriety product. I note there is reference in Danfoss manuals of a similar type of controller (101N0300) - AEO (Adaptive Energy Optimisation). Its description of function is exactly what I have observed occurring with the VMSO units.

As Quoted......... "In AEO (Adaptive Energy Optimizing) speed mode the BD compressor will always adapt its speed to the actual cooling demand."



As my FM70 consumes 50Ah in the same conditions as the CF80 (2.5 times the power), I would love to get a hold of this 101N0300 controller and retro fit it to see what that could do for my excessive consumption. However, I suspect this will not be a cheap exercise. 
I also note Waeco has introduced a MkII version of VMSO. This is currently fitted to the new CFX range. On that, I note this new range has now gone away from Danfoss (now made Secop due to a business takeover) and have fitted their own "Waeco" compressor. No doubt an Asian manufactured copy of the BD35F. It seems their foray into cheaper compressors (for example the now non used Wanbao) is in a state of constant evolution. It will take some considerable time for this new "Waeco branded" compressor to prove itself such as the Danfoss unit has over many years. And on that, I say the jury is out on any of their product with this new compressor fitted.






Freezer results:   So seeing as this fridge is similar in size to my FM70, I decided a comparison as fridge/freezer test had also to be performed.

In the same conditions, the FM70 consumed 56Ah.

The CF80-DZ:

Set at - 9 degrees (as this is what the owner uses)

Internal temp max: 7.6/-9.7    (being fridge contents/freezer contents)

Internal temp min:  6.8/-9.7

Ambient Temp max:  24.8

Ambient Temp min:  20.6

Amps peak: 6.25

Amps running average: 3.6

Power Consumption: 26.6

Case temp:  5 degrees below ambient


So, compared to the FM70.....an impressive result in my opinion. So much so, I may even look into replacing the FM70.

To finish up this CF80-DZ test, I need to make a couple of comments.

The fan on this is noisy. Same as my FM70. If you sleep near it, it may drive you nuts. In my situation though, I have come to ignore this background noise.

I also think like I had to do with the FM70, the dividers need a bit of playing around with as the fridge temps jumped up to a higher level than I would prefer. A larger gap under the divider should bring those temps down closer to the recommended 5 degrees without sacrificing freezer temperatures. I also note that whilst I had to set the unit at 0 degree's for a fridge only content of 5 degree's, the unit all but matched the freezer content when in fridge freezer mode.


*****************************************************************************************************************************************

2nd EDIT: March 2014

ARB 78L:




I have also got hold of an ARB 78L to test. This is invaluable as it is performed back to back with the CF80.

Things to note. This unit feels like it is built like a "brick shithouse". The metal sides and intergrated plastic feels so much heavier duty than any of the other fridges I've tested to date. Lid included. Mind you part of my testing isn't to bash the sided in with a brick......But I can tell you, the casing and lid appear to be far superior than any other I've had my hands on.

It has also been designed from the ground up by with someone with some knowledge on what is required for a travelling fridge in this country. The internals are neatly sized for correct can spacing, the lid hinge is bullet proof, the lid locking mechanism isn't a cheap afterthought and the tie down handles do not protrude the casing (A big advantage on a big fridge where space constraints become an even bigger burden).  What more can I say, on face value this oozes quality. But it's the test results I'm more interested in. So here we go:


Set at 2 degrees on the panel:

Internal temp max: 5.0

Internal temp min: 4.4

Ambient Temp max:  26.5

Ambient Temp min:  23.6

Amps peak: 8.4

Amps running average: 4.3

Power Consumption: 15.9

Case temp:  4 degrees below ambient


Some interesting results in there. The weird one is the Peak draw of 8.4Amps. I tested this 3 days in a row, resetting the meter each time and the same peak was measured. That is by far the largest peak I have ever seen.

Also I have to ask....does it ever run? I struggled to get cycle times on this unit cause it barely ever ran. Is that due to the heaviness of the case and its insulation???? noting it was a full one degree better in the case temperature test over the CF80. What cycle times I did gather was it powered on for 8 minutes but rested for 45 odd minutes. So it did about one cycle per hour compared to 3 for the CF80.

And I think that is shown in the power consumption stakes. 15.9Ah for the 24 hour period. Size for size, one of the most efficient I've tested to date. About 25% better than the similar sized CF80. Or about equal to the CF50-DZ.

Top effort there. But for me personally, the functionality of a dual zone would mean I have to take a power hit. If a DZ isn't on your bucket list and you are researching a large fridge, you would have to give the ARB 78L very serious consideration.

*****************************************************************************************************************************************

3rd EDIT: March 2014


Techni-ice GNA-60: 






Its all go this month. I have now got a hold of a Techni-Ice GNA60. This will be a very intriguing test for me as we now move away from Fulisawa and Danfoss. Techni-Ice are renowned for their ice boxes and freezer packs. Will this spill over to their fridge range?


This unit is powered by the Italian Domus compressor. What alarms me before the test is the specs show an average comsumption of 1.5 A/hour or in equal terms 36Ah in a 24 hour period. That seems quite high, however lets let the test results speak for themselves.


Set at 7 degrees on the panel:

Internal temp max: 4.9

Internal temp min:  4.1

Ambient Temp max:  26.2

Ambient Temp min:  22.7

Amps peak: 9.7

Amps running average: 3.0

Power Consumption: 14.2

Case temp: 5 degrees below ambient



So to make some comments here.......It used half the power it was specified as using. But those figures are at 32 deg's ambient with a content of -2 to +2 degrees. I think the 14.2 achieved was a good result considering its size. I would take the CF50-DZ as its direct comparison (but bear in mind the DZ's evaporator plate is only in the freezer side, so there would have to be some loss there due to thermal transfer). One strange thing over the others is the fact I had to set the temperature higher than was actually recorded. All others have been the reverse.

I like the fact it has a full, flush stainless evaporator plate. No chance of rubbing holes through refrigerant gas tubes. The Domus compressor must be the quiestest of any unit I've ever ran. Infact it was so quiet, I never really got the chance to measure compressor cycle/rest times. I also note, this is equiped with a controller that varies compressor speed acording to demand, just like Waeco's VMSO. At start up you could watch the amps slowly fall away, but then at times throughout the cycle, you could hear the motor wind up and watch the amps rise correspondingly. So a nice neat feature to have. I cant see any mention of this on their site. it also had the highest measured peak Amps of any I've tested. Why, I do not know, the few startups I witnessed were in the 5 amp range.

I note from the manufacturers literature that it also has a delayed start. One you turn it on, it may take 5 minutes to fire the compressor into action. I wonder why this is???? One thing I dont like about it though is the main on/off switch being a toggle down by the power cord inlet. If something was to roll around or move whilst the fridge is in the rear of the car, and it bumped this toggle, you could end up with a fridge that was inadvertantly turned off.

But overall, a very good result. The fact that this is the cheapest off all the units I've tested above (by a long margin in some instances), you would have to give a unit like this due consideration.

*****************************************************************************************************************************************

EDIT: March 2015

Waeco CFX50:




Coming soon.


Boasting a host of new features, including Waeco's all new home grown compressor (no doubt a clone of the Danfoss and made in china) and featuring a MKII variant of Waeco's VSMO. It will be very interesting to compare this with the CF50DZ and the Engel 40 I have data for. I'm hopeful of good results, cause I just purchased the fridge in this test on a hunch that it will be similar to the CF50DZ result, as I can find no data to back up my hunch. That said, I have been conversing with one who has tested his CFX60 along the same lines as my testing above. The results of that look very promising.

So enough jibber jabber, on to the testing results:

Preliminary results (I've only had it in my possession for a day)-

Set at 2 degrees on the panel:

Internal temp max: x

Internal temp min:  1.5

Ambient Temp max:  25.3

Ambient Temp min:  19.3

Amps peak: 4.1

Amps running average: 3.5

Power Consumption: 9.5 Ah

Case temp: x degrees below ambient


So I note that a 2 deg setting is keeping the content at that temperature. Next I will up the setting to 4 degs to try to keep content nearer the 5 degree target. I also note is low consumption. This is a good thing, however the ambient is a bit lower than in my other tests. So I will re do the test, set at 4 degrees and with the Engel40 side by side to show a comparative result in identical ambients.

Stay tuned.




*****************************************************************************************************************************************
How they compare over 24 hours